Chinese
English
 
 
 
 
 
 
Tel£º0086 0573-87952636
Fax£º0086 0573-87950950
M.P£º0086 15157312771
Add£ºDalin Industrial Zone, Huangwan Town, Haining Zhejiang China.
E-mail£ºsales@magsolar.com
 
Technology
 
Evacuated Tube Heat Pipe Collector Efficiency

Heat Pipe

Heat pipes might seem like a new concept, but you are probably using them everyday and don¡¯t even know it. Laptop computers often using small heat pipes to conduct heat away from the CPU, and air-conditioning system commonly use heat pipes for heat conduction.
The principle behind heat pipe¡¯s operation is actually very simple.
heat pipe is hollow with the space inside evacuated, much the same as the solar tube. In this case insulation is not the goal, but rather to alter the state of the liquid inside. Inside the heat pipe is a small quantity of purified water or Heat conduction oil.

At sea level water boils at 100oC (212oF), but if at the top of a mountain the boiling temperature will be less than 100oC (212oF).
This is due to the difference in air pressure. Based on this principle of water boiling at a lower temperature with decreased air pressure, by evacuating the heat pipe, we can achieve the same result. when the heat pipe is heated above 30oC (86oF) the water vaporizes. This vapour rapidly rises to the top of the heat pipe transferring heat. As the heat is lost at the condenser (top), the vapour condenses to form a liquid (water) and returns to the bottom of the heat pipe to once again repeat the process.

Quality Control
Material quality and cleaning is extremely important to the creation of a good quality heat pipe. If there are any impurities inside the heat pipe it will effect the performance. The purity of the copper itself must also be very high, containing only trace amounts of oxygen and other elements. If the copper contains too much oxygen or other elements, they will leach out into the vacuum forming a pocket of air in the top of the heat pipe. This has the effect of moving the heat pipe¡¯s hottest point (of the heat condenser end) downward away from the condenser. This is obviously detrimental to the performance of the heat absorption.

Prior to evacuation, the condenser is brazed to the shaft. Note that the condenser has a much larger diameter than the shaft, this is to provide a large surface area over which heat transfer to the header can occur. The copper used is oxygen free copper, thus ensuring excellent life span and performance.
Each heat pipe is tested for heat transfer performance and exposed to 250oC (482oF) temperatures prior to being approved for use.

Freeze Protection
Even though the heat pipe is a vacuum and the boiling point has been reduced to only 25-30? (86oF), the freezing point is still the same as water at sea level, 0? (32oF). Because the heat pipe is located within the evacuated glass tube, brief overnight temperatures as low as -20? (14oF) will not cause the heat pipe to freeze. Plain water heat pipes will be damaged by repeated freezing. The water used in?Interma heat pipes still freezes in cold conditions, but it freezes in a controlled way that does not cause swelling of the copper pipe.
a.The parameter of the heat pipe



 

 
 

 

About Us   |  Contact Us Products Show
Copyright (c) 2006-2007 magsolar.com All Rights reserved.
Haining Meige Solar Water Heater Co,.Ltd
Tel:0086-573-87952636 Fax:0086-573-87950950 E-mail:sales@magsolar.com